FEATURES

·         AC input voltage:  180~264Vac; 50-60Hz

·         AC input current:  < 15A @ 230VAC

·         Power Factor  > 0.99

·         Efficiency:  Max 93.5% typical

·         Noise level  < 45dB

·         Protection Level:  IP67

·         LED Display on the top side

·         CAN bus with auxiliary 12Vdc supply, can extend three colored LEDs

·         Charging protection below 0 ⁰C for Lithium (LI) Chargers

·         Temperature compensation of Lead Acid (LA) chargers

 

PROTECTION FUNCTIONS

·         Over current protection

·         AC Input under voltage protection

·         Output short circuit protection

·         Battery reversed protection

·         No-load protection

·         Over temperature protection




Comments
No comments received
Suppliers
Room 811, B4, Phase I, Guanghui Business Center, No.63, Sangyuan road, Dongcheng district, Dongguan, China
Product details
Comments

3600W Fast Charge Sealed Battery Charger Specification

 

DESEN ADS series of high frequency PWM chargers have a compact and sealed structure design, they are suitable for flooded lead acid batteries, sealed lead acid batteries and Lithium ion batteries. They are used to cycle charge or floating charge batteries in electric cars, Clean sweeper, sightseeing vehicles, patrol vehicles, forklifts, communication, AGV, electric power, boats, Lawn-Mowers, Agriculture Equipment, etc.

 

Active PFC and LLC new technology guarantee a good Power Factor and a very high efficiency.  The reliable hardware protections and Impeccable charging strategies ensure a safe charging process.

MODEL LIST

Model Name

Nominal Output

Voltage(V)

Max Charging Current (A)

Battery Type

ADS3600-24100XXX

24

100

> SLA : Sealed Lead-Acid ( AGM or GEL)

> FLA:  Flooded Lead-Acid ( Wet)

> LCO: Lithium Cobalt Oxide(LiCoO2) - (3.60V nominal; range 3.0-4.2V/cell)

> LMO: Lithium Manganese Oxide (LiMn2O4) - (3.70V nominal; range 3.0-4.2V/cell)

> NMC: Lithium Nickel Manganese Cobalt Oxide   (LiNiMnCoO2) (3.60V, 3.70V nominal; range 3.0-4.2V/cell)

> LFP: Lithium Iron Phosphate(LiFePO4)(3.20, 3.30V nominal range   2.5-3.65V/cell)

> NCA: Lithium Nickel Cobalt Aluminum Oxide   (LiNiCoAlO2)(3.60V nominal; range 3.0-4.2V/cell)

> LTO: Lithium Titanate (Li2TiO3)(2.40V nominal; range 1.8-2.85V/cell)

ADS3600-4850XXX

48

50






















  XXX: Battery type (use SLA, FLA, LCO…indicate the model)

 

KEY FEATURES 

·         AC input voltage range:  180~264Vac; 50-60Hz

·         AC input rated current:  <15A @ 230VAC

·         Power Factor  > 0.99

·         Efficiency:  Max 93.5%

·         Noise level < 45dB

·         Protection Level:  IP67

·         LED display on the top side

·         CAN bus with auxiliary 12Vdc supply, can extend three colored LEDs

·         Charging protection below 0 ⁰C for Lithium (LI) Chargers

·         Temperature compensation of Lead Acid (LA) chargers

·         Integrated die casting structure, pouring sealed inside the charger, good performance in vibration, active heating dissipation, high reliability and long life time, it can be adopted in hostile environment.

 

PROTECTION FUNCTIONS 

Over current protection

Yes

AC Input under voltage protection

When AC voltage <150Vac, the charger   will switch off

Output short circuit protection

Yes, will automatic resume after short is   removed

Battery reversed protection

yes

No-load   protection

yes

Over temperature

The charger must be able to operate up to   45 and will   de-rate the charge current linearly to 50% when reaching 60. When the   case reaching >65 the charger is allowed to stop, when the temperature falls, the   charger automatically resumes. No defects at high temperatures

Temperature compensation

For the lead-acid charger the NTC is used   for temperature compensation at -4mV/⁰C per 2V cell;
  the length of NTC cable is 1 meter

For the Lithium charger the external   temperature sensor
  is used to prevent charging < 0
ambient temperature

Fan cooling

The Fan rotates at charging and stops after   fully charged

Fully charged automatic disconnect

Only for Lithium version by internal relay

Fault LED indication

Yes, see chapter LED indicators

 

SAFETY AND ENVIRONMENT 

Safety test AC to DC

≤20mA@2000Vac/1min

Safety test AC to CASE

≤20mA@2000Vac/1min

Safety test DC to CASE

≤20mA@1000Vac/1min

Insulation Resistance test

AC to CASE > 100MΩ/DC 500V

Working ambient temperature

-30 …+65⁰C ; 45…60⁰C linear de-rating to 50%

Storage temperature

-40 …+80⁰C

Humidity

20…90 % RH

 

LED INDICATORS 

LED Indication Label


For LI Battery       For LA Battery

Non Load Status

Red and Green LED cross flash

Battery Capacity Status

Red LED flash per second, to show capacity < 80%

Yellow LED flash per second, to show capacity> 80%

Green LED flash per second, to show capacity = 100%

Fault Status

Over-volt/current protection: flash R-G-R...

Ambient temperature too high or low: flash R-G-R-G...

Over temperature: flash G-R...

Output under-voltage: flash R-G...

Input AC voltage abnormal: flash R-G-R-G-R...

Other faults: flash G-R-G...

Fully charged

Green LED light

 

 

GENERAL 

Dimension(mm)

354x202x108

N.W(kg)

5.8

G.W(kg)

6.94

Input

4 m2 AC cable with customized AC plug

Output

6 m2 with Grey SB175 or customized connector

Installation Type

Portable with Handle bar or On-board installation, FAN cover plate to   protect FAN

Warranty (Year)

2

 

                                          

DIMENSIONS 


 

 

USER ATTENTION 

·         Read these instructions and warnings before use.

·         The Charger must be used within Operating Ambient Temperature range -20~60 and humidity of < 90%

·         Do not place the charger outside, but always in a space that has some protection from outside weather influences

·         When the charger is installed, a minimum of 20 mm space all around the charger is needed.

·         Do not place the charger in a small not vented space; the charger will run hot.

·         The Charger must be yearly maintained, the air-flow slot which under the green plate must not be blocked, all dust and dirt substances must be cleaned. Check if the fan is operating properly during charging

·         Make sure the wires are placed in such a way that they cannot be damaged easily.

·         If the charger is used for electric vehicles like cars or boats, the interlock connection can be used to prevent the propulsion motor from starting during charge

·         The Lithium Battery must have a BMS protection with balancing the cells

·         The Lithium version of the charger will not charge below 0 ⁰C.

·         Place the NTC temperature sensor close to the battery

·         Never charge dead or damaged batteries

·         Do not attempt to disassemble the charger